• 1 Post
  • 47 Comments
Joined 2 days ago
cake
Cake day: November 21st, 2025

help-circle
  • Devial@discuss.onlinetoMildly Infuriating@lemmy.worldBritish plugs
    link
    fedilink
    English
    arrow-up
    2
    ·
    edit-2
    51 minutes ago

    Stick your finger in a 20A outlet, and you’ll pull out a burned finger. Stick your finger in a 100A outlet, and you’ll lose your hand, or your life. More power will pass through you before the circuit can be interrupted

    Did you just deliberately ignore everything I wrote ? Both 20 and 100amps are several hundred times more current than it needs takes to kill you. And the resistance of your body is way to high to pass more than a few hundred milliamps anyway.

    For a given voltage, the outcome of recieving a shock on a 20A fused circuit is literally indistinguishable and fully identical to that of receiving a shock on a 100A fused circuit. Identical. Literally.

    Our appliance wiring is rated to carry 20A from the receptacle throughout the appliance, or to a secondary current limiter within the appliance. Since the wiring is rated to the 20A the circuit can provide, we don’t need the secondary fuse in the plug. This is part of our appliance wiring standards.

    No it isn’t. I literally just told you you can buy 15A rated extension cords in Japan in the comment you’re replying to. 15, is in fact less than 20, just fyi. Are you deliberately ignoring half of what I wrote ?

    Obviously. That has been part of my point the entire time: You use fewer, higher wattage circuits. UK circuits carries more power to pass through your body than a comparable circuit elsewhere in the world. The household wiring standards in the rest of the world are more restrictive than they are in the UK. You are repeating the exact points that I (and others) have been making from the start.

    Wrong. Again. The current limit imposed by the internal resistance of your body at voltages in the range of 100-200 is a few hundred milliamps. Maybe an amp or two if you stick electrodes inside yourself, and anything higher than 100 going through your heart is lethal anyway. The power that will pass through your body depends exclusively and solely on the voltage. The capacity and fusing of the circuit is utterly irrelevant, unless it’s fused at like 40 MILLI amps.

    UK ring circuits are fused at 30 Amps.

    Man I fucking love how you literally just picked out the first line in a comment pointing out another one of the things you said that are objectively untrue (a dead short not blowing a UK ring fuse) and ignore everything else in the comment. You must have seen the comment to quote part of it, and yet you ignore it entirely. You’re clearly and demonstrably not arguing in good faith.

    Reread my comments from the start

    That’s fucking rich, when I’ve literally explicitly addressed every single point you made, whilst you seemingly deliberately ignore half the ones I make. Literally repeating falsehoods I disproved in the comment you’re replying to, whilst you’re replying.


  • Devial@discuss.onlinetoMildly Infuriating@lemmy.worldBritish plugs
    link
    fedilink
    English
    arrow-up
    1
    ·
    edit-2
    1 hour ago

    Breakers on UK household circuits are designed to allow considerably more power than comparable breakers around the world.

    That is utterly irrelevant. Circuit breakers and fuses are designed for the exclusive and sole purpose of protecting the circuit from being overloaded. A 100 amp circuit with a 100 Amp fuse is exactly as safe as a 20 amp circuit with a 20 amp fuse or a 5 amp circuit with a 5 amp fuse. If the voltage is above ~100-200V, all 3 of these are hundreds of times the amount of current it would take to deliver a fatal electric shock, and none of those fuses would trip from you getting shocked.

    To protect humans from electric shock we use residual current devices, which trip at 10’s of Milli amps. And here’s actually an advantage of a ring circuit. It forces you to place RCD protection on every single outlet in the building, instead of skimping on costs by just putting it on the branches that legally require one, like bathrooms and kitchens.

    Those fuses are not needed in Japanese (or North American, or most other) plugs. We don’t need to protect the “external wiring” separately from the household wiring: the household circuit breaker is rated lower than the “external wiring”. Drawing a direct short on the “external wiring” in a UK circuit is not sufficient to trip the UK circuit breaker in the UK distribution panel; they need a secondary current limiter (a fuse) to provide that function.

    That’s just demonstrably untrue. An individual branch of a household circuits in both the US or Japan can easily be fused at 20A (fun fact: European branch circuis, because of the higher voltage that you were raging against in your first comment, can handle more electric load whilst having SMALLER 16A breakers). In both Japan and America you can buy extension cords rated for 10 or 15A. So no. You just told a straight up, unequivocal lie there. And a dead short on a 240V network will literally trip everything. UK ring circuits are fused at 30 Amps. A dead short at 240V with only the internal resistance of copper wiring would pull current in the neighborhood of 1000 amps. 1000, somewhat famously, being slightly larger than 30, making this another lie there.

    And even if it weren’t a lie, how on earth does the location of the fuse make a difference in safety here ? If it’s in the wall or in the plug, as long as it’s there and does it’s job both would be equally safe.

    The function provided by those shutters is achieved in the Japanese wiring by lower voltage, narrow holes in receptacles (allowable because they don’t need as large a contact to safely carry the lower rated current) and whole-house AFCI/GFCI.

    No it isn’t. 110V is still dangerous to a child, and if you think otherwise I hope to god you aren’t, or ever become a parent. Also, as I stated, your plugs literally allow for an electric shock to happen whilst unplugging them because they’re so terrible. As for whole house GFCI, that is by necessity included in a ring circuit that wants GFCI on any outlet at all.

    Also you seem to fundamentally misunderstand the relationship of current and voltage. For a given electrical appliance, with a given wattage, a lower voltage means it needs to draw more current, not less. That’s why the US Japan need to have 20A household breakers, whereas in the EU 16A branches are more than enough, whilst still providing a higher load handling capability than a 20A Japanese fuse. A 1000 Watt microwave plugged into a Japanese socket will draw over twice as much current as a 1000 Watt microwave plugged into an EU or UK socket (which also means it produces 4 times the amount of electrical waste energy as heat, though that is generally negligible for short household cable runs either way. Can make a difference on the scale of a country though).

    And don’t think I didn’t notice you just quietly avoided responding to any of my arguments pointing out the obvious falsehoods in your voltage claim.

    Frankly, at this point, all you’ve done is utterly convince me that you are totally and utterly unqualified to speak on this topic. Almost every claim you make is wrong. And not even just “slightly oversimplified/technically incorrect” wrong, just straight up demonstrably untrue.


  • Devial@discuss.onlinetoMildly Infuriating@lemmy.worldBritish plugs
    link
    fedilink
    English
    arrow-up
    3
    ·
    edit-2
    2 hours ago

    The higher voltage has nothing whatsoever to do with ring circuits. The UK runs on the same 220-240V AC as all of mainland Europe. And Africa. And most of mainland Asia. And South America. And Oceania. And most of the middle east. So not quite “higher than any other country”

    Also those two claims are diametrically opposed to each other. Unless UK people use over twice the amount of electricity than Americans, the higher voltage will lead to LOWER total current. That’s quite literally the specific and sole motivating factor behind choosing a higher grid voltage.

    And the current a conductor can pass has nothing whatsoever to do with it’s safety. You could have 50 amps blowing through a circuit, if it’s at 12V you can still touch it without getting a shock. Your car battery is capable of peak currents of several HUNDRED amps, and those are considered safe enough to just carry around by random people with bare hands.

    Again, the amount of current passed depends only on the voltage, which again, is the same in the UK as all of mainland Europe (and most of the rest of the world except America and Japan), and has been since the early 20th century, so I’ve no idea what you’re trying to go on about there.

    And lastly, no it isn’t. For one, the child safety shutters on all UK outlets are certainly not contained in a Japanese breaker panel. Neither are the fuses in the plug, which protect the external wiring. And nor is the insulation on the lower legs of the contacts contained in a breaker panel. The Japanese plugs are basically the same as American. You can literally get an electric shock if you hold them wrong whilst unplugging. There’s exposed live contacts from when you start unplugging until the prongs break their connection to the outlet.

    Basically everything you said is demonstrably false. I’ve rarely seen someone be this confident and this incorrect about something.



  • Devial@discuss.onlinetoGames@lemmy.worldGaming Pet Peeves
    link
    fedilink
    English
    arrow-up
    4
    ·
    3 hours ago

    I mean that is kinda exactly what the developers want to provoke with timed dialogue choices. Timed dialogue choices are a game design mechanic to try and get a player to answer on instinct/gut feeling, rather than over analysing and trying to optimise the dialogue.

    You not getting to think about it long is very much the intended effect, and allowing a pause would entirely defeat it.

    There are of course definite accessibility concerns that should be considered and worked around, such as people with dyslexia who may not be able to properly parse the dialogue options before the timer runs out, but as a game mechanic I think forcing the player to pick on instinct definitely has merit. It helps make the game more immersive, because it puts you under the same pressure to react as your character is in the story right now, and it can lead to more interesting and ultimately enjoyable games by forcing players to potentially make a mistake, and having to find out a way to deal with the fallout.


  • Devial@discuss.onlinetoGames@lemmy.worldGaming Pet Peeves
    link
    fedilink
    English
    arrow-up
    7
    ·
    edit-2
    3 hours ago

    Games that don’t allow you to pause and skip cutscenes.

    I don’t want to have to miss half of the cutscenes just because someone interrupted me or the phone rang or something half way through. Alternatively, when I’m on my 23rd replay of a game, I do not want to have to sit through every cutscenes I already know by heart.

    Oh, and modern games that allow manual saving at any time, not having any kind of regular auto save (looking at you here BG3).

    If you’re fine from a gameplay pov with having the player save whenever, then there’s really no good reason whatsoever to not have one or two auto save slots that get saved every 10-20 minutes or so, at least as an option in the menu. ESPECIALLY in open world games (like BG3…) where you can easily go literal hours at a time without hitting a checkpoint save. And yes, I am still salty over learning about BG3’s lack of regular auto save when I lost like 2.5 hours of progress on my first run.


  • Fun fact, basic ethanol works excellent as a fuel additive to reduce knocking, but because it’s already a well known compound, fuel companies couldn’t patent it as an additive, that’s why they invented leaded petrol instead, so they could patent it.

    (E: For full completeness, it should probably also be noted that potential legal difficulties surrounding reliably obtaining or producing industrial quantities of Ethanol alcohol in prohibition era America probably also played some role, but the patent thing was definitely the main reason)




  • It’s possible to that of course, but I doubt it’s worth it. It also couldn’t be adapted as is, because fuses in each plug are always required t for UK plugs, they aren’t for EU plugs. And if you have to adapt a narrow EU plug to hold a replacable fuse would eat into size savings, require adapting the standard and require entirely new production lines for the modified plugs, so almost certainly simply not worth it.


  • Dude. Larger spaced economy seats would LITERALLY be doing the same exact thing. There is no world where you get more space for the same amount of money.

    Airlines already don’t make a lot of profit on economy seats, if any. It’s not like they’re price gauging you on the basic economy price. The majority of their profit comes higher classes, baggage and other service upgrades, and at least in America, credit card reward programs. Economy class by itself is already barely, if at all, profitable. Making it significantly more spacious will inevitably and without doubt lead to higher prices. And if you’re willing to pay those higher prices, we’ll that’s literally already an option today. The only thing you’re advocating for here is forcing literally everyone to pay that upcharge, even those that don’t want or need it.

    It’s also bad for the environment. As uncomfortable as it is, stuffing as many people as you possibly can into one aircraft reduces the total number of aircrafts/size of aircraft required for a certain passenger number. Not that that’s why airlines do it of course, but it’s a genuinely desirable and positive side effect of the cramped economy seating.



  • Devial@discuss.onlinetoMildly Infuriating@lemmy.worldBritish plugs
    link
    fedilink
    English
    arrow-up
    6
    ·
    edit-2
    5 hours ago

    No, because the rest of the world isn’t America.

    Those ring circuits WERE up to UK standard, and perfectly safe when they were constructed, and nowadays are either still covered by the standard, or grandfathered in, meaning at minimum in existing buildings, they still in fact are up to UK standard.

    The reason other counties don’t use ring circuits isn’t because they’re less safe or inherently worse in any way, which the term “substandard” clearly implies. It’s because they’re less convenient. It’s easier and more convenient to make and use, and easier in terms of individual steps, to make safe seperate fused circuits instead of a ring circuit.

    The reason the UK used ring circuits was because they use much less copper conduit, and given the massive copper everything shortage in the UK during and after WWII, the convenience of modern circuits simply wasn’t worth it.


  • I don’t see any reason to really insist on keeping characters their original class, unless you explicitly want that class in your party.

    I find respecing characters to different classes is a great way to allow you to choose which companion storylines you want to persue, without locking you into a specific class comp, and there’s plenty of class changes that imo stay perfectly in character.

    For example oath of vengeance paladin is very easy to integrate into Karlachs backstory and character. Shart would work well character wise as a shadow magic sorcerer.

    I can also totally see Astarion being a wizard, as I stated above, especially a Bladesinger.



  • I’m sorry you have to deal with that but it’s not really a good argument. For one, the airline can still actually sell the seat in front of you.

    If a person is so large they physically block 2 seats, then that’s an extra seat that can’t be occupied at all, so it’s not really a fair comparison.

    And ultimately, not every mode of transport can reasonably be accommodating to every single possible body type. I know that it sucks for people are stuck being an untypical body type and have to deal with nothing much fitting them, but what do you suggest the alternative should be ? Spacing seats out more just so the few very tall people can sit everywhere is going to increase ticket prices for everyone, even those who neither need nor want that extra space. It will also increase the number of flights required to move the same number of passengers, and therefore increase the fuel use per passenger and mile flown.


  • I mean they literally DON’T charge you for extra cabin weight, or body weight, even if they could. Most airlines don’t even put weight limits on cabin luggage, only size limits. And even those that have weight limits, in my experience, very rarely enforce them. Generally, only size is enforced for hand luggage.

    And they only charge overweight people double if they’re so large they physically block more than one seat, which imo is fine. If you need more than seat, it’s perfectly fine to expect you to pay for that extra seat. It has absolutely nothing whatsoever to do with either excessive greed OR mass/fuel issues.


  • I mean making shadowheart a light domain cleric when her literal goddess (at least if you’re still in Act1 ) is literally the goddess of darkness isn’t exactly in character, so I wouldn’t see anything wrong e.g. respecing Astarion to a wizard. He’s 200 years old, he’s had plenty of time to study and I’d say him being a wizard is less out of character than Shar Shadowheart being a light domain cleric…



  • No it isn’t. Not in large airplanes. The typical takeoff weight of an A320 is in the neighborhood of 50-70 tons. The pilots do not give a shit if a few passengers weigh a couple 100kg more than the average, and that’s a narrow body. A couple PAX being grosly obese on a widebody, with typical takeoff weights in excess of 100 tons, is even more negligible.

    Fuel calculations and weight&balance is calculated based on assumed average weights for men, women and children, generally something in the neighborhood of 85kg for men, 75 for women and 30-40 for children (includes assumed average hand luggage weight as well)